Page 5 - Dine
P. 5
ATM _ Air Turbine Machine / Air Spindle
Max RPM Run-out Coolant System Collet size Air Pressure Power
General : 2 Bar /
50,000 5 μm C 1mm~6mm 0.47 HP
ATC : 2.5 Bar
※ Based on spindle ※ Based on regulator
General Type
Rear air INLET Air regulator
How to use How to use
• Use in an equipment able to spray air on • Connect an external air hose
the main axis • Connect it directly to the regulator and
• Able to perform ATC as there is no external minimize the introduction of foreign substances
air hose to be connected
Precautions
Precautions • Must separate the hose from the product
• When spraying the air on the main axis, in case of ATC
be careful about introduction of foreign • Be careful when the main axis rotates
substances like oil
Auto Tool Change Type
ATC
How to use
• It is able to perform ATC and equipment
rotation even on equipment with no air main
axis penetration, so it can be automated
• The air is supplied on the Positioning Block,
so ATC and equipment spindle rotation is
possible
• The main axis can rotate at a low-speed,
and the tool length can be corrected
Basic Components_Spare Part
Components AIR SPINDLE AIR REGULATOR PC 12-03 SPANNER
Images
Quantity 1 1 2 1
Optianal Components
HC Collet Positioning block
Designation ØD1 L MAX.ØD Clearance
ØD ØD1
L HC6ØD(P) 10.5 25.0 6.0 1.0
DINOX NEW PORDUCTS ㅣ 05